Home › Microbiology › OMI › K120572

Bioplex 2200 Torc Igg (K120572)

Cleared · Substantially Equivalent FDA 510(k) premarket notification from Bio-Rad Laboratories, Inc., decided March 26, 2012.

510(k) number
K120572
Decision
March 26, 2012
Received
February 27, 2012
Review time
28 days
Applicant
Bio-Rad Laboratories, Inc.
Location
Benicia, CA, United States
Product code
OMI · Multiplex Flow Immunoassay, T. Gondii, Rubella And Cmv
Device class
Class 2
Regulation
21 CFR 866.3510
Review panel
Microbiology
Submission type
Special
Summary / statement
Summary
Third-party review
No
Contact
Juang Wang

What this clearance means

Bio-Rad Laboratories, Inc. submitted 510(k) K120572 for the Bioplex 2200 Torc Igg on February 27, 2012. The FDA found the device substantially equivalent to a legally marketed predicate device on March 26, 2012, which allows it to be marketed in the United States under product code OMI (Multiplex Flow Immunoassay, T. Gondii, Rubella And Cmv, Class 2). The FDA review took 28 days, faster than the median of 223 days for product code OMI.

Product code OMI definition: The kit is a multiplex immunoassay intended for the quantitative detection of IgG antibodies to Toxoplasma gondii (T. gondii) and Rubella, and qualitative detection of Cytomegalovirus (CMV) IgG in human serum and/ or plasma. Indicated as an aid in the determination of serological status to T. gondii, Rubella and CMV. This kit is not intended for use in screening blood or plasma donors.

Other Multiplex Flow Immunoassay, T. Gondii, Rubella And Cmv clearances (OMI)

510(k)DeviceApplicantDecision
K080008Bioplex 2200 System Torc Igg Kit, Calibrator Set and Control SetBio-Rad Laboratories, Inc.2009-02-23

All 2 OMI clearances →

More 510(k)s from Bio-Rad Laboratories, Inc.

510(k)DeviceDecision
K183446BioPlex 2200 Lyme Total2019-03-12
K181661QXDx BCR-ABL %IS Kit for use on the QXDx AutoDG ddPCR System2019-02-13
K180577BioPlex 2200 25-OH Vitamin D Kit2018-06-22
K171664Hemoglobin Variants System on Newborn Hemoglobin System with GDM and HbReview Software2017-09-13
K170509BioPlex 2200 ToRC IgM, BioPlex 2200 ToRC IgM Calibrator Set, BioPlex 2200 ToRC IgM Control Set2017-05-19
K170413BioPlex 2200 Syphilis Total & RPR, BioPlex 2200 Syphilis Total & RPR Calibrator Set, BioPlex 2200 Syphilis…2017-05-11
K163015Liquichek Tumor Marker Control-Level 1; Liquichek Tumor Marker Control-Level 2; Liquichek Tumor Marker…2017-01-10
K161687D-10 Hemoglobin A1c Program2016-10-14
K152679Amplichek I, Negative , Amplichek I, Level 1, Amplichek I, Level 2, Amplichek I, Level 3, Amplichek I, MiniPak2016-05-10
DEN150058Amplichek II, Negative and Amplichek II, Negative MiniPak, Amplichek II, Level 1 and Amplichek II, Level 1…2016-03-28

All 128 clearances from Bio-Rad Laboratories, Inc. →

FAQ

Is the Bioplex 2200 Torc Igg FDA cleared?

Yes. FDA 510(k) K120572 received the decision "Substantially Equivalent" on March 26, 2012.

Who makes it?

The 510(k) holder is Bio-Rad Laboratories, Inc., Benicia, CA, United States.

How long did the FDA review take?

28 days from receipt to decision.