Reprocessed IntellaMap Orion High Resolution Mapping Catheter (K211662)
Cleared · Substantially Equivalent FDA 510(k) premarket notification from Innovative Health, LLC, decided November 18, 2021.
- 510(k) number
- K211662
- Decision
- November 18, 2021
- Received
- June 1, 2021
- Review time
- 170 days
- Applicant
- Innovative Health, LLC
- Location
- Scottsdale, AZ, United States
- Product code
- NLG · Catheter, Intracardiac Mapping, High-Density, Reprocessed
- Device class
- Class 2
- Regulation
- 21 CFR 870.1220
- Review panel
- Cardiovascular
- Submission type
- Traditional
- Summary / statement
- Summary
- Third-party review
- No
- Contact
- Rick Ferreira
What this clearance means
Innovative Health, LLC submitted 510(k) K211662 for the Reprocessed IntellaMap Orion High Resolution Mapping Catheter on June 1, 2021. The FDA found the device substantially equivalent to a legally marketed predicate device on November 18, 2021, which allows it to be marketed in the United States under product code NLG (Catheter, Intracardiac Mapping, High-Density, Reprocessed, Class 2). The FDA review took 170 days, slower than the median of 140 days for product code NLG.
Other Catheter, Intracardiac Mapping, High-Density, Reprocessed clearances (NLG)
| 510(k) | Device | Applicant | Decision |
|---|---|---|---|
| K260574 | Reprocessed Carto Octaray Mapping Catheter with Trueref Technology | Innovative Health, LLC | 2026-11-11 |
| K212776 | Reprocessed Advisor HD Grid Mapping Catheter, Sensor Enabled | Innovative Health, LLC | 2021-12-20 |
| K190785 | Reprocessed PentaRay Nav eco High-Density Mapping Catheter | Innovative Health, LLC | 2019-06-25 |
More 510(k)s from Innovative Health, LLC
| 510(k) | Device | Decision |
|---|---|---|
| K260574 | Reprocessed Carto Octaray Mapping Catheter with Trueref Technology | 2026-11-11 |
| K262917 | Reprocessed BRK Transseptal Needle | 2026-10-19 |
| K250305 | Reprocessed Agilis NxT Steerable Introducer | 2026-01-07 |
| K231015 | Reprocessed Super Torque and Super Torque Plus Diagnostic Angiographic Catheters | 2024-07-01 |
| K233825 | Reprocessed Webster Duo-Decapolar Diagnostic EP Catheter | 2024-06-07 |
| K232037 | Reprocessed VersaCross Steerable Sheath; Reprocessed SureFlex Steerable Guiding Sheath | 2024-04-04 |
| K230376 | Reprocessed Agilis NxT Steerable Introducer | 2023-08-07 |
| K213584 | Reprocessed NRG Transseptal Needle | 2023-04-04 |
| K221854 | Reprocesses Umbilical Cable | 2022-08-06 |
| K210655 | Reprocessed Eagle Eye Platinum RX Digital IVUS Catheter | 2022-05-25 |
All 52 clearances from Innovative Health, LLC →
FAQ
Is the Reprocessed IntellaMap Orion High Resolution Mapping Catheter FDA cleared?
Yes. FDA 510(k) K211662 received the decision "Substantially Equivalent" on November 18, 2021.
Who makes it?
The 510(k) holder is Innovative Health, LLC, Scottsdale, AZ, United States.
How long did the FDA review take?
170 days from receipt to decision.