Home › Cardiovascular › QYX › K240029

Zio AT® device (A100A1001) (K240029)

Cleared · Substantially Equivalent FDA 510(k) premarket notification from iRhythm Technologies, Inc., decided October 21, 2024.

510(k) number
K240029
Decision
October 21, 2024
Received
January 4, 2024
Review time
291 days
Applicant
iRhythm Technologies, Inc.
Location
San Francisco, CA, United States
Product code
QYX · Outpatient Cardiac Telemetry
Device class
Class 2
Regulation
21 CFR 870.1025
Review panel
Cardiovascular
Submission type
Traditional
Summary / statement
Summary
Third-party review
No
Contact
Vishal Kanani

What this clearance means

iRhythm Technologies, Inc. submitted 510(k) K240029 for the Zio AT® device (A100A1001) on January 4, 2024. The FDA found the device substantially equivalent to a legally marketed predicate device on October 21, 2024, which allows it to be marketed in the United States under product code QYX (Outpatient Cardiac Telemetry, Class 2). The FDA review took 291 days, slower than the median of 155 days for product code QYX.

Product code QYX definition: Devices are intended to continuously record and analyze electrocardiograms for automatic detection and recording of cardiac electrical activity in an outpatient setting. Detected, notifiable events are transmitted to the prescribing clinician during the monitoring period by a 24/7 attended analysis center after review by a qualified individual. Devices may allow remote access and display of electrocardiograms acquired. Not for use for detection or notification of hemodynamically unstable or life-threatening arrhythmias or cardiac events requiring urgent medical response. Not intended for patients at elevated risk of serious cardiovascular events that would require prompt intervention. It is not intended for monitoring patients during cardiac rehabilitation outside of healthcare facilities. Devices are intended for prescription use only.

Other Outpatient Cardiac Telemetry clearances (QYX)

510(k)DeviceApplicantDecision
K250793RhythmStar System (SL)RhythMedix, LLC2026-04-21
K241179Rhythm Express Remote Cardiac Monitoring System (RX-1 mini)VivaQuant, Inc.2025-07-11
K240653SmartCardia 7L Platform (MCT)Smartcardia SA2024-10-31
K233584RhythmStar SystemRhythMedix, LLC2024-07-08
K162956Nowcardio SystemContex International Technologies (Canada), Inc.2017-09-22
K170565LifeWatch Mobile Cardiac Telemetry 3 Lead LifeWatch MCT 3LLifewatch Services, Inc.2017-08-01
K163512Zio AT ECG Monitoring SystemiRhythm Technologies, Inc.2017-06-02
K160064MoMe Kardia Wireless Ambulatory ECG Monitoring and Detection SystemInfobionic, Inc.2016-03-11
K133753Mome Ecg Continuous Detection and Arrhythmia DetectorInfobionic, Inc.2014-09-19
K133701Nuvant Mct SystemCorventis, Inc.2014-02-06

All 21 QYX clearances →

More 510(k)s from iRhythm Technologies, Inc.

510(k)DeviceDecision
K252859ZEUS Platform (FG0501US)2026-05-29
K243650Zio® monitor (DFG0001)2025-08-15
K240177Zio AT® device (A100A1001)2024-10-30
K222389ZEUS System2023-02-15
K213409ZEUS System (Zio Watch)2022-07-19
K202527Zio ECG Utilization Software (ZEUS) System2021-05-21
K202359Zio Monitor2021-05-21
K190593Zio XT ECG Monitoring System, Zio AT ECG Monitoring System2019-08-23
K181502Zio AT ECG Monitoring System, ZEUS System2018-08-29
K163512Zio AT ECG Monitoring System2017-06-02

All 18 clearances from iRhythm Technologies, Inc. →

FAQ

Is the Zio AT® device (A100A1001) FDA cleared?

Yes. FDA 510(k) K240029 received the decision "Substantially Equivalent" on October 21, 2024.

Who makes it?

The 510(k) holder is iRhythm Technologies, Inc., San Francisco, CA, United States.

How long did the FDA review take?

291 days from receipt to decision.